MULTACOM Datacenters offer complete redundancy in power, HVAC, Pre-Action, fire suppression (FM-200), network connectivity and security, incorporating raised flooring (DC1 & DC3), dual power grids, UPS battery backup power and diesel generators.

Slider Image
Slider Image
Slider Image
Slider Image
Slider Image
Slider Image
Slider Image
Slider Image
Slider Image
Slider Image
Slider Image
Slider Image

Three primary MULTACOM Data Centers are located on the 4th floor of 707 Wilshire Blvd. in downtown Los Angeles, This location enables us to connect easily to virtually any backbone provider and scale our internet connectivity to meet client's needs. Additionally the Network is directly connected via diverse path Fiber Optic lines to many of the other carrier buildings in downtown such as One Wilshire and 818 W. 7th and 530 W. 6th street, which host our network equipment and/or are used as expansion data center space. Services offered at these datacenters include private caged suites, cabinets, half-cabinets and rack space.

Datacenters are continuously monitored via video surveillance cameras and 24 hour on-site security personnel. With use of sophisticated two-tier access control systems.

Access to 4th floor, elevators as well as the Datacenters individually is restricted and controlled via HID contact-less access control system (floor access and DC1 and DC2) and Biometric access control systems (DC4). Being the only teant on the 4th floor limits access to the entire floor provides additional security.

Power

DC1 and DC2 employ 2(N+1) Design, power is provided via two active feeds from two power busses which are connected to separate and independent Diesel Generators and finally backed up by two redundant UPS systems. In addition to the most fault tolerant system in both datacenters, Datacenter 1 (Suite 405) also has an additional power source with its own UPS backup system providing divergent power supply. Our other data centers utilize N+1 redundancy which backs up ctritical load with Generator and UPS battery power in case of utility power loss.

  • Datacenter 1: 110V, 220V and 48V DC Power can be provisioned.
  • Datacenter 2: 110V 20A Circuits.
  • Datacenter One Wilshire: 208V/220V 5A 10A 20A Circuits
  • Datacenter 530 NAC: 208V/220V 5A Metered 10A Metered 20A Circuits
  • Datacenter 4: 208/220V 5A Metered, 10A, 20A Circuits

Cooling

Both datacenters DC1 and DC2 employ redundant set of 11 HVAC systems which are controlled by an automated software. One set of the HVAC units (Primary Set) utilizes building chilled water and the other set (Secondary Set) utilizes dedicated chillers which are on the side of the building and are independent of buildings chilled water supply.

DC4 our newest data center to go online offers new Libert CW cooling systems. Four 20TON units and 2 10TON units cool this data center combined with hot air exhust.   Stackable chiller dedicated to this suite is able to benefit from building Primary chilled water if required for additonal reliablity.

Network

The location uses diverse conduit paths to many other carrier buildings in downtown Los Angeles. Redundant Dark fiber between each connected building and divergent path to many of the carrier buildings ensures unsurpassed network reliability at this location.

Juniper Networks Cisco River Stone Networks Juniper Networks

Buy Risk Free 7 day Money Back Guarantee • Free & Fast Hardware Repair • Real Time Bandwidth Monitoring Access
Free Remote Hands • Secure Facitily • Cisco & Juniper Routers/Switches • Free Remote Reboot Plug • Free Reboots
Redundant Lieber Climate Control Systems • Free Port Monitoring • Cicso & Microsoft Certified Engineers
UPS & Diesal Power Generator